Showing results: 46 - 60 of 338 items found.
-
AS-023A -
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
YD-Series -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication
-
TRM 1000 -
AJIT Electronics Co.
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
-
-
Neutronics Manufacturing Co.
Variac Auto Transformers are continuously variable voltage auto transformer, having a movable carbon tip, fixed to a brush-arm sliding on a silver plated commutator. Rotation of the brush-arm by either manual or motor drive, delivers-an output voltage from zero to or above line voltage.
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
HDZK -
HD Power Test Equipment Co.ltd
Low voltage short circuit impedance test is to identify the shock of short circuit on the transformer on the operation, which is the direct method of checking the winding distortion after transformers hit by mechanical forces during transportation and installation.Short circuit impedance test is an important parameter to decide the running or disassembling inspection for transformer .Transformer Short Circuit And Impedance Tester is a new development instrument suitable for testing low voltage short short circuit impedance 35kV transformer in the field and labor
-
Osborne Transformer Corp.
Osborne’s Control Transformers are commonly used to step down primary circuit voltages to lower voltages to be used for control circuit applications. These units set the standard for premium, high performance, hand crafted control transformers. Your customers will appreciate your decision to work with the quality and reliability of Osborne Transformer’s control transformers.
-
Handheld Turns Ratio & Winding Resistance Tester TWR-H -
Amperis sl
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Entes Elektronik
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
Osborne Transformer Corp.
Osborne designs and produces high impedance and unregulated Filament Transformers. An unregulated filament transformer supplies a specified voltage and current to the filament of an electron vacuum tube. High impedance filament transformers are designed around a tungsten tube filament. Osborne often works with our clients to increase the life-span of their vacuum tubes through the use of a regulated voltage supply.
-
TYPE JF -
Shanghai Jiuzhi Electric Co., Ltd.
TYPE JF Partial Discharge Shielding Room (Factory Building) is suitable for the partial discharge experiment and impact test in different voltage band (110KV, 220KV, 500KV, 750KV,1000KV) of cable, voltage transformer, transformer, switch, and power station etc.
-
GIT GIS -
HV Hipot Electric Co.,Ltd.
GIT GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer,high voltage coupling capacitors and all components in a sealed space.High voltage generated with two modes:using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.The other one is to obtain required high voltage directly from high voltage transformer.
-
T 3000 -
Altanova Group
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers